Goodman Heat Pump Thermostat Not Working

Here is what you need to do.
Goodman heat pump thermostat not working. If not your system may have a valve problem a refrigerant charge issue or a compressor problem. If you have a dual fuel system you will need to have a trained professional set up your thermostat. If your home has a heat pump the thermostat or control system should be able to control the auxiliary heat function. If it is specific to a gas furnace you may not be able to control this function.
First of all just check and make sure your unit was not accidentally switched to a c mode. All the correct 24 volts are coming to the five wires coming from the air handler to the heat pump. Over time the compressor unit in the goodman central air system may fail. 2 be sure the room heating registers are open.
A two stage or variable speed system may only be operating at a single speed because the thermostat or control system doesn t allow for two. It will also need to be replaced by a technician. Blowing cold in heat mode. If the heat does not come on even when the thermostat is set above room temperature then you probably have a blown fuse or a tripped circuit breaker.
As the name suggests the reversing valve allows the heat pump to work as both a heater and an air conditioner by reversing the direction of the refrigerant. The tables below are the lists of possible issues which you may encounter having goodman heat pump not working. Heat pump troubleshooting problem 3. And then wait a few minutes for the heat to come on.
There is no 24 volts on the yellow wire on the defrost control board that leads to the. Heat pumps look similar to air conditioners so check the label on your outdoor unit to make sure it s a heat pump. 3 check the heat pump. There are the descriptions for different goodman modifications gpc1336m41 r 410a and n2h3.
In case your heat pump is not working at all the problem is usually with the unit receiving power or with the thermostat. Next check your outdoor unit is not iced over see heat pump troubleshooting problem 1. 1 be sure the thermostat is set properly. Heat pump not heating.
The compressor pumps a refrigerant gas to dehumidify and cool the air. If you re still not sure which system you have contact a local pro. Goodman heat pump won t run. My goodman heat pump is not working the fan and the compressor.
If the heat pump turns on when you want cool air but not for heat this is likely the cause. It also removes heat and moisture from the air inside your home by circulating the warm air over the indoor coil and pumping it to the outside of your home and pumping the cool air inside. Raise the set temperature 5 degrees f.